BACKGROUND: Allergic contact dermatitis caused by (meth)acrylates is well known, both in occupational and in non-occupational settings. Contact hypersensitivity to electrocardiogram (ECG) electrodes containing (meth)acrylates is rarely reported. OBJECTIVE: To report the first case of contact dermatitis caused by acrylic acid impurity in ECG electrodes. MATERIALS AND METHODS: Patch tests were performed with separate components of electrodes and some (meth)acrylates. This was followed by high-performance liquid chromatography of electrode hydrogel. RESULTS: The patient was contact-allergic to electrode hydrogel but not to its separate constituents. Positive reactions were observed to 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl methacrylate (2-HPMA) and ethyleneglycol dimethacrylate (EGDMA). Subsequent analysis showed that the electrode hydrogel contained acrylic acid as an impurity. The latter was subsequently patch tested, with a positive result. CONCLUSION: The sensitization resulting from direct contact with ECG electrodes was caused by acrylic acid, present as an impurity in ECG electrodes. Positive reactions to 2-HEMA, 2-HPMA and EGDMA are considered to be cross-reactions.

The role of acrylic acid impurity as a sensitizing component in electrocardiogram electrodes

Stingeni, L
Conceptualization
;
Cerulli, E
Investigation
;
Spalletti, A;Mazzoli, A;Bianchi, L
Investigation
;
Hansel, K
Conceptualization
2015

Abstract

BACKGROUND: Allergic contact dermatitis caused by (meth)acrylates is well known, both in occupational and in non-occupational settings. Contact hypersensitivity to electrocardiogram (ECG) electrodes containing (meth)acrylates is rarely reported. OBJECTIVE: To report the first case of contact dermatitis caused by acrylic acid impurity in ECG electrodes. MATERIALS AND METHODS: Patch tests were performed with separate components of electrodes and some (meth)acrylates. This was followed by high-performance liquid chromatography of electrode hydrogel. RESULTS: The patient was contact-allergic to electrode hydrogel but not to its separate constituents. Positive reactions were observed to 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl methacrylate (2-HPMA) and ethyleneglycol dimethacrylate (EGDMA). Subsequent analysis showed that the electrode hydrogel contained acrylic acid as an impurity. The latter was subsequently patch tested, with a positive result. CONCLUSION: The sensitization resulting from direct contact with ECG electrodes was caused by acrylic acid, present as an impurity in ECG electrodes. Positive reactions to 2-HEMA, 2-HPMA and EGDMA are considered to be cross-reactions.
2015
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/1320513
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 27
social impact