The numerical and analytical models used for transient simulations, and hence for the pressurized pipe system diagnosis, require the definition of a rheological component related to the pipe material. The introduction and the following widespread use of polymeric material pipes, characterized by a viscoelastic behavior, increased the complexity and the number of parameters involved in this component with respect to metallic materials. Furthermore, since tests on specimens are not reliable, a calibration procedure based on transient test is required to estimate the viscoelastic parameters. In this paper, the trade-off between viscoelastic component accuracy and simplicity is explored, based on the Akaike criterion. Several aspects of the calibration procedure are also examined, such as the use of a frequency domain numerical model and of different standard optimization algorithms. The procedure is tested on synthetic data and then it is applied to experimental data, acquired during transients on a high density polyethylene pipe. The results show that the best model among those used for the considered system implements the series of a spring with three Kelvin–Voigt elements.

Comparison of viscoelastic models with a different number of parameters for transient simulations

Ferrante, M.
;
Capponi, C.
2018

Abstract

The numerical and analytical models used for transient simulations, and hence for the pressurized pipe system diagnosis, require the definition of a rheological component related to the pipe material. The introduction and the following widespread use of polymeric material pipes, characterized by a viscoelastic behavior, increased the complexity and the number of parameters involved in this component with respect to metallic materials. Furthermore, since tests on specimens are not reliable, a calibration procedure based on transient test is required to estimate the viscoelastic parameters. In this paper, the trade-off between viscoelastic component accuracy and simplicity is explored, based on the Akaike criterion. Several aspects of the calibration procedure are also examined, such as the use of a frequency domain numerical model and of different standard optimization algorithms. The procedure is tested on synthetic data and then it is applied to experimental data, acquired during transients on a high density polyethylene pipe. The results show that the best model among those used for the considered system implements the series of a spring with three Kelvin–Voigt elements.
2018
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/1421140
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 19
social impact