A gravity damper is a one-way valve, employed for regulating the airflow rate in ducts, generally constituted by a series of rectangular panels (closure sections), connected to an articulated quadrilateral synchronizing the movements. If the device needs to process large masses of high speed air, as common in the case of energy conversion systems, disadvantageous dynamic effects can occur. In this study, vortex- induced vibration (VIV), occurring on a gravity damper for high values of the Reynolds number, is investigated. The analysis of this work couples numerical methods (Computational Fluid Dynamics with Large-Eddy Simulation turbulence model and Finite Element Method) to experiments: a full-scale accelerometric measurement campaign is actually performed at the wind tunnel facilities of the University of Perugia. VIVs are diagnosed and quantified through the experimental vibration analysis, which is interpreted through numerical simulations. The large amplitude of VIV is interpreted as due to a tendency towards lock- in because of the approaching of the vortex shedding frequency to a natural vibration mode of the system. The integrated numerical and experimental framework finally inspires two different design solutions for mitigating the amplitude of VIV: these strategies are tested at the wind tunnel and they are indeed shown to be effective.

Diagnosis of vortex induced vibration of a gravity damper

Lorenzo SCAPPATICCI;Francesco CASTELLANI;Davide ASTOLFI
;
Alberto GARINEI
2018

Abstract

A gravity damper is a one-way valve, employed for regulating the airflow rate in ducts, generally constituted by a series of rectangular panels (closure sections), connected to an articulated quadrilateral synchronizing the movements. If the device needs to process large masses of high speed air, as common in the case of energy conversion systems, disadvantageous dynamic effects can occur. In this study, vortex- induced vibration (VIV), occurring on a gravity damper for high values of the Reynolds number, is investigated. The analysis of this work couples numerical methods (Computational Fluid Dynamics with Large-Eddy Simulation turbulence model and Finite Element Method) to experiments: a full-scale accelerometric measurement campaign is actually performed at the wind tunnel facilities of the University of Perugia. VIVs are diagnosed and quantified through the experimental vibration analysis, which is interpreted through numerical simulations. The large amplitude of VIV is interpreted as due to a tendency towards lock- in because of the approaching of the vortex shedding frequency to a natural vibration mode of the system. The integrated numerical and experimental framework finally inspires two different design solutions for mitigating the amplitude of VIV: these strategies are tested at the wind tunnel and they are indeed shown to be effective.
2018
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/1428484
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact