IEEE Calibration of microwave radiometers is a crucial task for reliable and accurate antenna temperature measurements in remote sensing applications. This paper describes a processing procedure for data calibration of noise-adding (NA) total power (TP) radiometers, without thermal stabilization, able to improve the radiometric resolution performance and keep good accuracy. This method, easily implementable, is based on the strong dependence of the radiometric gain on the internal physical temperature of the system. It provides a calibration of the output voltage measured in the TP mode exploiting the noise source power injection only every 30 min. The quality of the proposed procedure was assessed by means of three experiments carried out in different years and environmental conditions, using a low-cost NA TP radiometer operating at 12.65 GHz. The measurements show an uncertainty better than 0.7 K and, above all, a clear improvement in radiometric resolution (below 0.1 K). The radiometric resolution benefit is particularly appreciable in applications where the aim is the detection of small radiation power increments. Two experimental tests show how this method for data calibration effectively resolves the warm target counting inside the antenna footprint, while the same data measured with the standard NA procedure do not allow the same detection capability.

An Efficient Gain Estimation in the Calibration of Noise-Adding Total Power Radiometers for Radiometric Resolution Improvement

Bonafoni, S.
Membro del Collaboration Group
;
Alimenti, F.
Membro del Collaboration Group
;
Roselli, L.
Membro del Collaboration Group
2018

Abstract

IEEE Calibration of microwave radiometers is a crucial task for reliable and accurate antenna temperature measurements in remote sensing applications. This paper describes a processing procedure for data calibration of noise-adding (NA) total power (TP) radiometers, without thermal stabilization, able to improve the radiometric resolution performance and keep good accuracy. This method, easily implementable, is based on the strong dependence of the radiometric gain on the internal physical temperature of the system. It provides a calibration of the output voltage measured in the TP mode exploiting the noise source power injection only every 30 min. The quality of the proposed procedure was assessed by means of three experiments carried out in different years and environmental conditions, using a low-cost NA TP radiometer operating at 12.65 GHz. The measurements show an uncertainty better than 0.7 K and, above all, a clear improvement in radiometric resolution (below 0.1 K). The radiometric resolution benefit is particularly appreciable in applications where the aim is the detection of small radiation power increments. Two experimental tests show how this method for data calibration effectively resolves the warm target counting inside the antenna footprint, while the same data measured with the standard NA procedure do not allow the same detection capability.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/1431257
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact