In humans, accessory pathways (APs) in an anteroseptal and midseptal position are often challenging to ablate because of their close proximity with the conduction pathways of the atrioventricular junction. The use of low-energy ablation techniques can be useful to reduce the risk of permanently damaging the atrioventricular node and the His bundle. This report describes the use of low-energy radiofrequency catheter ablation to successfully and permanently ablate anteroseptal APs in two dogs with orthodromic atrioventricular reciprocating tachycardia. In the first dog, a transient first degree atrioventricular block persisted for 30 s after radiofrequency energy delivery. In the second dog, transient paroxysmal atrioventricular conduction block was observed during the procedure but resolved within 3 days. First degree atrioventricular block was again identified 2 months later. In conclusion, anteroseptal APs can be effectively treated by low-energy radiofrequency catheter ablation with minimal and transient damage to the atrioventricular junction.

Low-energy ablation of anteroseptal accessory pathways in two dogs

Caivano, D;Birettoni, F;Porciello, F;
2018

Abstract

In humans, accessory pathways (APs) in an anteroseptal and midseptal position are often challenging to ablate because of their close proximity with the conduction pathways of the atrioventricular junction. The use of low-energy ablation techniques can be useful to reduce the risk of permanently damaging the atrioventricular node and the His bundle. This report describes the use of low-energy radiofrequency catheter ablation to successfully and permanently ablate anteroseptal APs in two dogs with orthodromic atrioventricular reciprocating tachycardia. In the first dog, a transient first degree atrioventricular block persisted for 30 s after radiofrequency energy delivery. In the second dog, transient paroxysmal atrioventricular conduction block was observed during the procedure but resolved within 3 days. First degree atrioventricular block was again identified 2 months later. In conclusion, anteroseptal APs can be effectively treated by low-energy radiofrequency catheter ablation with minimal and transient damage to the atrioventricular junction.
2018
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/1443258
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact