The scientific literature focusing on the numerical simulation of fuel sprays is rich in atomization and secondary break-up models. However, it is well known that the predictive capability of even the most diffused models is affected by the combination of injection parameters and operating conditions, especially backpressure. In this paper, an alternative atomization strategy is proposed for the 3D-Computational Fluid Dynamics (CFD) simulation of Gasoline Direct Injection (GDI) sprays, aiming at extending simulation predictive capabilities over a wider range of operating conditions. In particular, attention is focused on the effects of back pressure, which has a remarkable impact on both the morphology and the sizing of GDI sprays. 3D-CFD Lagrangian simulations of two different multi-hole injectors are presented. The first injector is a 5-hole GDI prototype unit operated at ambient conditions. The second one is the well-known Spray G, characterized by a higher back pressure (up to 0.6 MPa). Numerical results are compared against experiments in terms of liquid penetration and Phase Doppler Anemometry (PDA) data of droplet sizing/velocity and imaging. CFD results are demonstrated to be highly sensitive to spray vessel pressure, mainly because of the atomization strategy. The proposed alternative approach proves to strongly reduce such dependency. Moreover, in order to further validate the alternative primary break-up strategy adopted for the initialization of the droplets, an internal nozzle flow simulation is carried out on the Spray G injector, able to provide information on the characteristic diameter of the liquid column exiting from the nozzle.

Impact of the primary break-up strategy on the morphology of GDI sprays in 3D-CFD simulations of multi-hole injectors

Cavicchi A.
Investigation
;
Postrioti L.
Writing – Review & Editing
2019

Abstract

The scientific literature focusing on the numerical simulation of fuel sprays is rich in atomization and secondary break-up models. However, it is well known that the predictive capability of even the most diffused models is affected by the combination of injection parameters and operating conditions, especially backpressure. In this paper, an alternative atomization strategy is proposed for the 3D-Computational Fluid Dynamics (CFD) simulation of Gasoline Direct Injection (GDI) sprays, aiming at extending simulation predictive capabilities over a wider range of operating conditions. In particular, attention is focused on the effects of back pressure, which has a remarkable impact on both the morphology and the sizing of GDI sprays. 3D-CFD Lagrangian simulations of two different multi-hole injectors are presented. The first injector is a 5-hole GDI prototype unit operated at ambient conditions. The second one is the well-known Spray G, characterized by a higher back pressure (up to 0.6 MPa). Numerical results are compared against experiments in terms of liquid penetration and Phase Doppler Anemometry (PDA) data of droplet sizing/velocity and imaging. CFD results are demonstrated to be highly sensitive to spray vessel pressure, mainly because of the atomization strategy. The proposed alternative approach proves to strongly reduce such dependency. Moreover, in order to further validate the alternative primary break-up strategy adopted for the initialization of the droplets, an internal nozzle flow simulation is carried out on the Spray G injector, able to provide information on the characteristic diameter of the liquid column exiting from the nozzle.
2019
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/1462426
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 13
social impact