The object of this paper is the Loccioni Leaf Lab, an industrial nZEB connected to a thermal and electric smart grid. Having nZEB buildings connected to a smart grid offers the possibility of maximizing the benefits that can be obtained by optimal regulation of the grid itself, providing excellent economic and energy results. The case study, which hosts offices and workers operating on test benches, features high performance envelope, solar photovoltaic systems, groundwater heat pumps and a hightechnology control and monitoring system. In order to analyse HVAC-related energy consumptions, the building was modelled using DesignBuilder and EnergyPlus software. The annual dynamic simulations for the assessment of building thermal-energy performance were carried out using available monitored weather data (2019). The model was validated according to ASHRAE guidelines, comparing the outputs of the software with data collected and stored by Company internal database. In the validation process, mean indoor air temperatures of several zones and heating and cooling energy consumptions were considered as key outputs. The validated model has then been used to suggest optimization strategies and to analyse the results obtained with proposed interventions in terms of energy saving.

Energy analysis, numerical simulations and intervention proposals for a NZEB industrial building: The Loccioni Leaf Lab case study

Stamponi E.;Lattanzi N.;Moretti E.
2021

Abstract

The object of this paper is the Loccioni Leaf Lab, an industrial nZEB connected to a thermal and electric smart grid. Having nZEB buildings connected to a smart grid offers the possibility of maximizing the benefits that can be obtained by optimal regulation of the grid itself, providing excellent economic and energy results. The case study, which hosts offices and workers operating on test benches, features high performance envelope, solar photovoltaic systems, groundwater heat pumps and a hightechnology control and monitoring system. In order to analyse HVAC-related energy consumptions, the building was modelled using DesignBuilder and EnergyPlus software. The annual dynamic simulations for the assessment of building thermal-energy performance were carried out using available monitored weather data (2019). The model was validated according to ASHRAE guidelines, comparing the outputs of the software with data collected and stored by Company internal database. In the validation process, mean indoor air temperatures of several zones and heating and cooling energy consumptions were considered as key outputs. The validated model has then been used to suggest optimization strategies and to analyse the results obtained with proposed interventions in terms of energy saving.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/1492002
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact