ABSTRACT: This work was undertaken to assess the long-term impacts of a ruminal transponder, used for electronic identification, on ruminal motility and on health and performance of cattle, as well as to study the electromagnetic effects on ruminal bacteria in vitro. A passive transponder (51.4 g, 67 × 17 mm) was delivered into the forestomachs of 8 calves, 32 bulls, 10 heifers, and 40 dairy cows. Final readability was 87.5% in calves, 96.9% in bulls, 90% in heifers, and 100% in cows at 481, 360, 650, and 601 d, respectively, after transponder administration. The transponder did not affect production or reproduction of cows over a 2-yr period, or performance of bulls, or mortality compared with control animals. Chewing movements per bolus were lower (P < 0.01) in treated animals than in controls (49.6 vs. 52.2, 51.2 vs. 63.6, and 57.0 vs. 59.7 for bulls, heifers, and cows, respectively). Regurgitation frequency (number of boluses/10 min) tended to be greater in treated cattle: 12.4 vs. 11.3 (P = 0.07), 11.3 vs. 10.6, and 11.3 vs. 10.7 (P = 0.08) for bulls, heifers, and cows, respectively. Rumination patterns of calves fitted with transponders within the first weeks of life were similar to controls. During the experiment, 43 treated animals (8 calves, 29 bulls, and 6 cows) were slaughtered. Thirty transponders were localized in the reticulum (3 calves, 24 bulls, and 3 cows), 11 in the rumen (4 calves, 4 bulls, and 3 cows), and 2 were not recovered (1 calf and 1 bull). Within the calves, 57% of the boluses were found in the rumen. In 8 reticula (2 calves and 6 bulls) and 1 rumen (1 cow), an impression left by physical contact of the transponder was observed, although histological examination did not reveal specific lesions in the mucosa of the dystrophic areas. In strained, whole ruminal contents incubated in vitro, pH values were lower after 24 and 48 h (P < 0.001) of continuous exposure to an electromagnetic field induced by the transponder-reading system. After 48 h of incubation, total bacterial numbers and NH3-N concentration were greater (P < 0.001) in exposed flasks than in controls. These data indicate that the transponder may alter, via mechanical action, the reticuloruminal mucosa and rumination patterns. Furthermore, the transponder may increase, via its electromagnetic action, the growth rate and metabolic activity of ruminal bacteria.

In vivo mechanical and in vitro electromagnetic side-effects of a ruminal transponder in cattle

TRABALZA MARINUCCI, Massimo;MUGHETTI, LAURA;ACUTI, GABRIELE;FABA, Antonio;ASDRUBALI, Giampaolo;BOITI, Cristiano
2006

Abstract

ABSTRACT: This work was undertaken to assess the long-term impacts of a ruminal transponder, used for electronic identification, on ruminal motility and on health and performance of cattle, as well as to study the electromagnetic effects on ruminal bacteria in vitro. A passive transponder (51.4 g, 67 × 17 mm) was delivered into the forestomachs of 8 calves, 32 bulls, 10 heifers, and 40 dairy cows. Final readability was 87.5% in calves, 96.9% in bulls, 90% in heifers, and 100% in cows at 481, 360, 650, and 601 d, respectively, after transponder administration. The transponder did not affect production or reproduction of cows over a 2-yr period, or performance of bulls, or mortality compared with control animals. Chewing movements per bolus were lower (P < 0.01) in treated animals than in controls (49.6 vs. 52.2, 51.2 vs. 63.6, and 57.0 vs. 59.7 for bulls, heifers, and cows, respectively). Regurgitation frequency (number of boluses/10 min) tended to be greater in treated cattle: 12.4 vs. 11.3 (P = 0.07), 11.3 vs. 10.6, and 11.3 vs. 10.7 (P = 0.08) for bulls, heifers, and cows, respectively. Rumination patterns of calves fitted with transponders within the first weeks of life were similar to controls. During the experiment, 43 treated animals (8 calves, 29 bulls, and 6 cows) were slaughtered. Thirty transponders were localized in the reticulum (3 calves, 24 bulls, and 3 cows), 11 in the rumen (4 calves, 4 bulls, and 3 cows), and 2 were not recovered (1 calf and 1 bull). Within the calves, 57% of the boluses were found in the rumen. In 8 reticula (2 calves and 6 bulls) and 1 rumen (1 cow), an impression left by physical contact of the transponder was observed, although histological examination did not reveal specific lesions in the mucosa of the dystrophic areas. In strained, whole ruminal contents incubated in vitro, pH values were lower after 24 and 48 h (P < 0.001) of continuous exposure to an electromagnetic field induced by the transponder-reading system. After 48 h of incubation, total bacterial numbers and NH3-N concentration were greater (P < 0.001) in exposed flasks than in controls. These data indicate that the transponder may alter, via mechanical action, the reticuloruminal mucosa and rumination patterns. Furthermore, the transponder may increase, via its electromagnetic action, the growth rate and metabolic activity of ruminal bacteria.
2006
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/152611
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact