In this paper, a new four-point probe, double spiral heating element configuration for micromachined gas sensors is proposed and a simple analytical model of the steady-state thermal behavior of the microheater is presented. A testing procedure is suggested, based on simple two-wire and four-wire resistance versus power measurements, together with an iterative extraction procedure for the parameters of the thermal model. This allowed us to accurately extract the sensor active area temperature as a function of the total power dissipated on the microheater.

Thermal characterization of a microheater for micromachined gas sensors

PLACIDI, Pisana;SCORZONI, Andrea
2004

Abstract

In this paper, a new four-point probe, double spiral heating element configuration for micromachined gas sensors is proposed and a simple analytical model of the steady-state thermal behavior of the microheater is presented. A testing procedure is suggested, based on simple two-wire and four-wire resistance versus power measurements, together with an iterative extraction procedure for the parameters of the thermal model. This allowed us to accurately extract the sensor active area temperature as a function of the total power dissipated on the microheater.
2004
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/152987
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 96
  • ???jsp.display-item.citation.isi??? 80
social impact