The CMS tracker consists of 206m(2) of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from -25 to + 25 degrees C. The mechanical stability of tracker components during physics operation was monitored with a few mu m resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011-2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30 mu m. In addition, temperature variations were found to cause displacements of tracker structures of about 2 mu m/degrees C, which largely revert to their initial positions when the temperature is restored to its original value.

Mechanical stability of the CMS strip tracker measured with a laser alignment system

A. Giammanco;H. S. Chen;Y. Chen;Z. Liu;A. Spiezia;F. Ferri;E. Locci;J. Andrea;M. Hamer;A. Modak;V. Jha;L. Fiore;A. Pompili;G. Pugliese;A. M. Rossi;S. Paoletti;G. Lanza;P. Paolucci;C. Riccardi;L. Alunni Solestizi;D. Ciangottini;L. Fanò;P. Lariccia;V. Mariani;A. Santocchia;L. Storchi;J. Bernardini;A. Messineo;G. Tonelli;A. Venturi;P. G. Verdini;L. Barone;E. Longo;G. Organtini;R. Covarelli;S. Cho;J. Lee;A. Di Francesco;D. Abbaneo;A. Bocci;Y. Chen;E. Di Marco;S. Martina;L. Orsini;W. Erdmann;L. Bianchini;F. Pandolfi;D. Salerno;G. Davies;R. Di Maria;G. Hall;M. Sani;C. George;M. Sun;A. Canepa;D. Christian;H. Wang;A. Penzo;A. Belloni;R. Barbieri;L. Di Matteo;
2017

Abstract

The CMS tracker consists of 206m(2) of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from -25 to + 25 degrees C. The mechanical stability of tracker components during physics operation was monitored with a few mu m resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011-2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30 mu m. In addition, temperature variations were found to cause displacements of tracker structures of about 2 mu m/degrees C, which largely revert to their initial positions when the temperature is restored to its original value.
2017
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/1547715
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 1
social impact