We propose a non-linear steady-state model of irreversible electropermeabilization in a biological tissue. The non-linear problem is solved using a modified fixed point iteration. The unknown parameters are experimentally estimated from the observation of the necrosis on a potato tissue for different applied voltages. A variability study of the parameters involved in the model is performed.

Non-linear steady-state electrical current modeling for the electropermeabilization of biological tissue

Scorretti R.;
2015

Abstract

We propose a non-linear steady-state model of irreversible electropermeabilization in a biological tissue. The non-linear problem is solved using a modified fixed point iteration. The unknown parameters are experimentally estimated from the observation of the necrosis on a potato tissue for different applied voltages. A variability study of the parameters involved in the model is performed.
2015
File in questo prodotto:
Non ci sono file associati a questo prodotto.