Extremely low frequency (ELF) electric fields (EF) and magnetic fields (MF) are generated during the production, transmission, and use of electrical energy. Although epidemiology studies suggest that there is a cancer risk associated with exposure to ELF-MF, short-term genotoxicity assays with bacteria and mammalian cells have produced inconsistent results. In the present study, we investigated the possible genotoxicity of ELF-MF by using the Tradescantia-micronucleus (Trad-MN) assay, a sensitive, reproducible, well-standardized assay for genotoxicity testing. A 50 Hz ELF-MF was generated by a laboratory exposure system consisting of a pair of parallel coils in a Helmholtz configuration. Exposure of Tradescantia (clone # 4430) inflorescences to the ELF-MF, at a flux density (B) corresponding to 1 mT, for 1, 6, and 24 h resulted in a time-dependent increase in MN frequency. The results indicate that a 50 Hz MF of 1 mT field strength is genotoxic in the Trad-MN bioassay and suggest that this assay may be suitable as a biomonitor for detecting the genotoxicity of ELF-MF in the field.

Genotoxic effects of Extremely Low Frequency (ELF) Magnetic Fields (MF) evaluated by Tradescantia-Micronucleus assay

FATIGONI, Cristina;DOMINICI, LUCA;MORETTI, Massimo;VILLARINI, Milena;MONARCA, Silvano
2005

Abstract

Extremely low frequency (ELF) electric fields (EF) and magnetic fields (MF) are generated during the production, transmission, and use of electrical energy. Although epidemiology studies suggest that there is a cancer risk associated with exposure to ELF-MF, short-term genotoxicity assays with bacteria and mammalian cells have produced inconsistent results. In the present study, we investigated the possible genotoxicity of ELF-MF by using the Tradescantia-micronucleus (Trad-MN) assay, a sensitive, reproducible, well-standardized assay for genotoxicity testing. A 50 Hz ELF-MF was generated by a laboratory exposure system consisting of a pair of parallel coils in a Helmholtz configuration. Exposure of Tradescantia (clone # 4430) inflorescences to the ELF-MF, at a flux density (B) corresponding to 1 mT, for 1, 6, and 24 h resulted in a time-dependent increase in MN frequency. The results indicate that a 50 Hz MF of 1 mT field strength is genotoxic in the Trad-MN bioassay and suggest that this assay may be suitable as a biomonitor for detecting the genotoxicity of ELF-MF in the field.
2005
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/164211
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 24
social impact