In this study we evaluated the capability of a 213 nm laser ablation system coupled to a quadrupole-based ICP-MS in delivering accurate and precise U-Pb ages on zircons and monazites. Four zircon samples (ca. 50 Ma to ca. 600 Ma) and four monazite samples (ca. 30 Ma to ca. 1390 Ma) of known ages were analysed utilising laser ablation pits with diameters of 20 μm and 60 μm. Instrument mass bias and laser induced time-dependent elemental fractionation were corrected for by calibration against a matrix-matched reference material. Tera-Wasserburg plots of the calculated U-Pb data were employed to assess, and correct for, common Pb contributions. The results indicated that the LA-ICP-MS technique employed in this study allowed precise and accurate U-Pb isotope dating of zircon and monazite on sample areas 20 μm in diameter. At this spot size, the precisions achieved for single spot 206Pb/238U ages, were better than 5% (2s) for monazites and zircons with ages down to 30 Ma and 50 Ma, respectively. The precisions reported are comparable to those generally reported in SIMS and LA-MC-ICP-MS U-Pb isotope determinations.
Micro-Analytical Zircon and Monazite U-Pb Isotope Dating by Laser Ablation-Inductively Coupled Plasma–Quadrupole Mass Spectrometry
ALAGNA, KEEGAN EDWARD;PETRELLI, MAURIZIO;PERUGINI, Diego;POLI, Giampiero
2008
Abstract
In this study we evaluated the capability of a 213 nm laser ablation system coupled to a quadrupole-based ICP-MS in delivering accurate and precise U-Pb ages on zircons and monazites. Four zircon samples (ca. 50 Ma to ca. 600 Ma) and four monazite samples (ca. 30 Ma to ca. 1390 Ma) of known ages were analysed utilising laser ablation pits with diameters of 20 μm and 60 μm. Instrument mass bias and laser induced time-dependent elemental fractionation were corrected for by calibration against a matrix-matched reference material. Tera-Wasserburg plots of the calculated U-Pb data were employed to assess, and correct for, common Pb contributions. The results indicated that the LA-ICP-MS technique employed in this study allowed precise and accurate U-Pb isotope dating of zircon and monazite on sample areas 20 μm in diameter. At this spot size, the precisions achieved for single spot 206Pb/238U ages, were better than 5% (2s) for monazites and zircons with ages down to 30 Ma and 50 Ma, respectively. The precisions reported are comparable to those generally reported in SIMS and LA-MC-ICP-MS U-Pb isotope determinations.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.