We have constructed and operated charge preamplifiers for silicon strip detectors with a dynamic range extending from fractions of minimum ionising particle (MIP) up to 16124 MIPs. These silicon detectors combined with time-of-flight counters and cesium iodide scintillator fern: a segment of the VENUS detector that has been exposed to a calcium beam of 0.5 GeV/u at the GSI accelerator. The aim of the instrument is the identification of all nuclides of the periodic table of the elements. Measurements of electronic noise, cross-talk among channels and energy deposit resolutions in various experimental conditions for silicon detectors are given. The measured light output of the CsI(Tl) crystal induced by calcium is compared with that extrapolated from lower-energy data of various nuclide species determined in other experiments. The charge resolution for calcium ions, determined by the dE/dx detectors and TOF counters of time resolution of. 55 +/- 7 ps, amounts to 0.42 charge units (rms). Improvements in ion discrimination with respect to the present detector configuration are considered.

Response of silicon multistrip detectors and a cesium iodide scintillator to a calcium ion beam of 0.5 GeV/u

CODINO, Antonio;VOCCA, Helios
1997

Abstract

We have constructed and operated charge preamplifiers for silicon strip detectors with a dynamic range extending from fractions of minimum ionising particle (MIP) up to 16124 MIPs. These silicon detectors combined with time-of-flight counters and cesium iodide scintillator fern: a segment of the VENUS detector that has been exposed to a calcium beam of 0.5 GeV/u at the GSI accelerator. The aim of the instrument is the identification of all nuclides of the periodic table of the elements. Measurements of electronic noise, cross-talk among channels and energy deposit resolutions in various experimental conditions for silicon detectors are given. The measured light output of the CsI(Tl) crystal induced by calcium is compared with that extrapolated from lower-energy data of various nuclide species determined in other experiments. The charge resolution for calcium ions, determined by the dE/dx detectors and TOF counters of time resolution of. 55 +/- 7 ps, amounts to 0.42 charge units (rms). Improvements in ion discrimination with respect to the present detector configuration are considered.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/166570
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact