High sound insulation ventilating windows (HSIVW) were recently proposed for noise control in buildings close to motorways or railways, where noise barriers are not effective or too expensive. These windows are characterized by good insulation performances and at the same time allow airflow through the window itself; such a performance matches summer indoor ventilation and refreshment needs. In the last years at the Acoustics Laboratory of the University of Perugia various prototypes were tested and their acoustic and airflow performances were assessed, also verifying the influence of filtering systems in the aerator. In the present paper a lot of experimental data are presented and in particular the results of a recent campaign, aimed at testing windows samples integrated with insulated rolling shutter boxes are presented. Sound reduction index R and single number sound reduction index Rw are evaluated, considering different exercise conditions; acoustic intensity measurements and analysis have also been performed, in order to verify the parts of the window which need to be optimized.

Sound intensity investigation of the acoustics performances of high insulation ventilating windows integrated with rolling shutter boxes

ASDRUBALI, Francesco;BURATTI, Cinzia
2005

Abstract

High sound insulation ventilating windows (HSIVW) were recently proposed for noise control in buildings close to motorways or railways, where noise barriers are not effective or too expensive. These windows are characterized by good insulation performances and at the same time allow airflow through the window itself; such a performance matches summer indoor ventilation and refreshment needs. In the last years at the Acoustics Laboratory of the University of Perugia various prototypes were tested and their acoustic and airflow performances were assessed, also verifying the influence of filtering systems in the aerator. In the present paper a lot of experimental data are presented and in particular the results of a recent campaign, aimed at testing windows samples integrated with insulated rolling shutter boxes are presented. Sound reduction index R and single number sound reduction index Rw are evaluated, considering different exercise conditions; acoustic intensity measurements and analysis have also been performed, in order to verify the parts of the window which need to be optimized.
2005
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/170472
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 18
social impact