This study describes the surgical technique and intra- and postoperative complications associated with the use of a radiofrequency bipolar coagulator in a series of 18 Piver type III-IV radical hysterectomies performed in cervical cancer patients. Preliminary vessel-by-vessel dissection of the lateral parametria was possible in 17 out of 18 (94\%) cases, and a direct application of a radiofrequency bipolar coagulation instrument was performed to coagulate the posterior and anterior parametrial tissues in all cases. We were able to easily coagulate isolated vessels up to 5 mm of maximal diameter. In no case were clamps or hemoclips necessary to complete hemostasis. We did not observe any parametrial vessel damage or heat-related injury of the surrounding normal tissue. The median size of the parametria removed was 44 mm (range 31-58) and nodes were detected in 15 cases (83\%). Median operative time and estimated blood loss for the whole procedure including systematic pelvic and aortic lymphadenectomy was 250 min (range 200-410) and 550 ml (range 400-2500), respectively. Median follow-up time was 9 months (range 5-13). No complications specifically related to the use of radiofrequency coagulation were found. In conclusion the radio-frequency coagulation with this instrument appears to be a safe technique that is particularly useful in reducing blood loss and operative time without affecting radicality in patients undergoing radical hysterectomy.

Radiofrequency bipolar coagulation for radical hysterectomy: technique, feasibility and complications.

FAGOTTI, Anna;
2003

Abstract

This study describes the surgical technique and intra- and postoperative complications associated with the use of a radiofrequency bipolar coagulator in a series of 18 Piver type III-IV radical hysterectomies performed in cervical cancer patients. Preliminary vessel-by-vessel dissection of the lateral parametria was possible in 17 out of 18 (94\%) cases, and a direct application of a radiofrequency bipolar coagulation instrument was performed to coagulate the posterior and anterior parametrial tissues in all cases. We were able to easily coagulate isolated vessels up to 5 mm of maximal diameter. In no case were clamps or hemoclips necessary to complete hemostasis. We did not observe any parametrial vessel damage or heat-related injury of the surrounding normal tissue. The median size of the parametria removed was 44 mm (range 31-58) and nodes were detected in 15 cases (83\%). Median operative time and estimated blood loss for the whole procedure including systematic pelvic and aortic lymphadenectomy was 250 min (range 200-410) and 550 ml (range 400-2500), respectively. Median follow-up time was 9 months (range 5-13). No complications specifically related to the use of radiofrequency coagulation were found. In conclusion the radio-frequency coagulation with this instrument appears to be a safe technique that is particularly useful in reducing blood loss and operative time without affecting radicality in patients undergoing radical hysterectomy.
2003
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/992258
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact