Several applications involving the use of Fibre Reinforced Polymers (FRP) glued on the tension side of timber beams are available in literature. However, some drawbacks (durability, product cost and health and safety restrictions, difficulties in removal) have limited an intensive use of organic adhesives (i.e. epoxy resins, etc). A possible solution could be the use of metal screws, changing the nature of the connection from chemical to mechanical.This paper describes an experimental investigation on the mechanical behaviour of externally bonded FRP composites using steel screws. Two different composite materials have been considered: Carbon Fibre Reinforced Polymer (CFRP) and Glass Fibre Reinforced Polymer (GFRP) and three different metal screw types have been used. FRP strengtheningwas then applied to timber blocks and shear tested conducted to study the performance of the screwed connection. The response of the screwed connection was recorded: catastrophic collapse did not occur, as the connection failed gradually for slippage phenomena produced by screw yielding and wood displacement. The slippage between timber and FRP plate has been recorded and tests described in this paper demonstrated that the effectiveness of screwed FRP strengthening could be compromised by these phenomena.

Shear resistance of screwed timber connections with parallel to grain FRP reinforcements

Marco Corradi
Formal Analysis
;
Antonio Borri
Supervision
2016

Abstract

Several applications involving the use of Fibre Reinforced Polymers (FRP) glued on the tension side of timber beams are available in literature. However, some drawbacks (durability, product cost and health and safety restrictions, difficulties in removal) have limited an intensive use of organic adhesives (i.e. epoxy resins, etc). A possible solution could be the use of metal screws, changing the nature of the connection from chemical to mechanical.This paper describes an experimental investigation on the mechanical behaviour of externally bonded FRP composites using steel screws. Two different composite materials have been considered: Carbon Fibre Reinforced Polymer (CFRP) and Glass Fibre Reinforced Polymer (GFRP) and three different metal screw types have been used. FRP strengtheningwas then applied to timber blocks and shear tested conducted to study the performance of the screwed connection. The response of the screwed connection was recorded: catastrophic collapse did not occur, as the connection failed gradually for slippage phenomena produced by screw yielding and wood displacement. The slippage between timber and FRP plate has been recorded and tests described in this paper demonstrated that the effectiveness of screwed FRP strengthening could be compromised by these phenomena.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11391/1448517
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact